Electrical Installation Condition Report
EICR form: the electrical installation condition report in an app
Fill in the EICR form on your phone, one circuit at a time. ClearWorks flags missing details and readings outside limits, sets the overall assessment from your codes, and sends the report before you leave. This page covers the form itself. For the whole electrical workflow, see our EICR software for electricians.
Last updated
- From £15 a month + VAT, unlimited certificates
- 3 free certificates, no card needed
What does the EICR form record?
The Electrical Installation Condition Report is the BS 7671 model form for reporting on an installation that is already in service. It is a report on condition, not a certificate for new work.
The model form asks for:
- who ordered the report, and why it is being produced
- the installation, and the extent and agreed limitations of the inspection
- an overall assessment, Satisfactory or Unsatisfactory
- your observations, each with a classification code
- the date you recommend for the next inspection, with your reasons
- your declaration and signature
Schedules of inspection, circuit details and test results go with it.
The codes, and what changed in Amendment 4
The BS 7671:2018+A4:2026 model forms are dated 15 April 2026. The transition period for Amendment 2:2022 ended on 15 October 2026. The A4 model EICR splits observations into two groups.
| Code | Wording on the form | Overall assessment |
|---|---|---|
| C1 | Danger present. Risk of injury. Immediate remedial action is necessary. | Unsatisfactory |
| C2 | Potentially dangerous. Urgent remedial action is necessary. | Unsatisfactory |
| C3 | Improvement recommended. | Not affected |
| FI | Further investigation is advised. | Not affected |
The form states that C3 and FI observations are advisory and do not affect the overall assessment. FI is for a potential issue you could not verify within the extent and limitations of the inspection. On the A2:2022 form, FI read “Further investigation required without delay” and the notes had the report marked Unsatisfactory.
Where practicable, a C1 is to be made safe on discovery. For typical examples of each code, see EICR codes C1, C2, C3 and FI explained.
Landlord EICRs in England
The Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020 put these duties on the landlord. They apply in England only. The changes that extend them to social housing came into force on 1 November 2025, and on 1 May 2026 for social tenancies granted before 1 December 2025. Scotland, Wales and Northern Ireland have their own rules.
- How often: inspected and tested by a qualified person before a tenancy starts, then at intervals of no more than 5 years, or by an earlier date if the last report gives one.
- Existing tenants: a copy of the report within 28 days of the inspection.
- New tenants: a copy of the most recent report before they move in. Government guidance says a new inspection is not needed before re-letting if the last one was less than 5 years ago and the report requires no further investigative or remedial work.
- Prospective tenants: within 28 days of a written request.
- Local housing authority: within 7 days of a written request.
- Next inspector: the landlord must pass a copy to whoever does the next inspection.
- Remedial or further investigative work: where the report requires it, within 28 days of the inspection, or sooner if the report says so.
- After the work: written confirmation from a qualified person, sent with the report to each tenant and the local housing authority within 28 days of completion.
Government guidance says that confirmation can be a Minor Electrical Installation Works Certificate.
Your report must give the landlord the results and the date by which the next inspection is due. For a registered provider of social housing that supplies electrical equipment, it must also say whether the checks on that equipment are up to date.
How ClearWorks handles the EICR form
- Guided one circuit at a time, to BS 7671:2018+A4:2026
- Zs checked against the protective device as you type
- A C1 or C2 makes the report Unsatisfactory
- Missing details and readings outside limits are flagged
- No signing with something missing, no sending without your registration number and signatures
- The landlord’s legal details on every report
- Works with no signal. It saves on the phone and sends when you’re back online
When you sign, the report goes to the landlord, agent and tenant with your logo. You get a record of when each one opened it. Agents can scan the QR code to check it was issued and is in date.
Found a C2? Turn the findings into a quote in one tap. When the job is done, raise a minor works certificate linked to the findings it fixes. Where the remedial work needs a new circuit or a consumer unit change, issue an Electrical Installation Certificate instead.
Reminders go to the landlord by email and text before the next inspection is due. They tap to book, and the job lands in your diary.
ClearWorks checks each report against the form’s rules. You remain responsible for the inspection, the codes and the report. ClearWorks is not affiliated with or endorsed by NICEIC, NAPIT or ELECSA.
EICR form questions
Is an EICR a certificate?
Strictly, no. It is a report on the condition of an existing installation. New work gets an Electrical Installation Certificate or a Minor Electrical Installation Works Certificate. Landlords and agents often call the EICR a certificate, so this page uses both words.
Does an FI make the EICR Unsatisfactory?
Not on the BS 7671:2018+A4:2026 model form. It says C3 and FI observations are advisory and do not affect the overall assessment. In England, a landlord must still have further investigation done within 28 days where the report requires it.
How often does a rented home in England need an EICR?
Before a tenancy starts, then at intervals of no more than 5 years, or by an earlier date if the last report gives one. Government guidance says a new inspection is not needed before re-letting if the last one was less than 5 years ago and the report requires no further investigative or remedial work. The landlord gives the new tenant a copy of that report.
Sources: IET, BS 7671:2018+A4:2026 model forms (Electrical Installation Condition Report, A4 form dated 15 April 2026 and A2:2022 form). IET, updates to the 18th Edition. Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020, regulation 3. GOV.UK, Electrical safety standards in the private and social rented sectors: guidance. Last checked 25 November 2026.
Related
Fill in your next EICR form in ClearWorks.
Your first 3 certificates are free. No card needed.
Founding London engineers keep their price for as long as they stay subscribed.