For gas engineers, plumbers and electricians moving into heat pumps and air conditioning.

F gas qualification: courses, categories and certificates

To install, repair or maintain air conditioning, heat pumps or refrigeration for customers in Great Britain, you need a personal F gas qualification in category 1, or category 2 within its size limit, and your business needs a company certificate, sole traders included. Category 2 covers systems under 3kg of F gas, or 6kg if hermetically sealed.

Last updated

F gas is refrigerant, not fuel gas

F gas is short for fluorinated greenhouse gas. GOV.UK lists three types: hydrofluorocarbons (HFCs), perfluorocarbons (PFCs) and sulphur hexafluoride (SF6). Defra says HFCs are commonly used in refrigeration, air conditioning and heat pumps.

They are regulated because of their global warming potential. Releasing F gas on purpose is banned unless it is technically necessary. GOV.UK says the UK is cutting HFCs by 79% by 2030, measured against average use from 2009 to 2012.

This page covers Great Britain, where the rules sit in Regulation (EU) No 517/2014 as kept in UK law and the Fluorinated Greenhouse Gases Regulations 2015. GOV.UK says Northern Ireland is part of the European Union F gas system.

This is a summary, not legal advice. Follow the current regulations and your certification body’s rules. You remain responsible for your own work. ClearWorks is not affiliated with GOV.UK, the Environment Agency, Defra, City & Guilds, BESA, LCL Awards, Refcom or any other awarding or certification body.

Who needs a personal qualification and a company certificate

The personal qualification belongs to the engineer. GOV.UK says you need your own even if you work for someone else. The company certificate belongs to the business.

F gas work on stationary and other equipment: what you need
WorkPersonal qualificationCompany certificateSource
Install, repair, maintain or decommission air conditioning, heat pumps or refrigeration for customersYes. Category 1, or category 2 inside its size limitYes, sole traders includedGOV.UK, qualifications; GOV.UK, companies
The same work on your own employer’s equipment onlyYesNoGOV.UK, companies
Leak check without breaking into the refrigeration circuitYes. Category 4 is enoughNot listed. GOV.UK names installing, repairing, maintaining and decommissioningGOV.UK, qualifications
Car and van air conditioning (recovery), or switchgear containing SF6Yes, but separate vehicle and switchgear qualificationsNo. GOV.UK exempts car and van air conditioning and high voltage switchgearGOV.UK, qualifications; GOV.UK, companies
Trainee enrolled on a course, supervised by a certificate holderExempt while training, for up to 24 months in totalThe business still needs one2015/2067, Article 3

Fire protection systems and solvents have their own qualifications, also listed on GOV.UK.

F gas categories 1 to 4 in plain English

  • Category 1: everything. Any size of system.
  • Category 2: install, maintain, service and recover refrigerant, but only on systems holding under 3kg of F gas, or under 6kg if hermetically sealed. The regulation also lets a category 2 holder leak check without breaking into the circuit.
  • Category 3: recovery only, with the same 3kg and 6kg limits.
  • Category 4: leak checks only, and only where you do not break into the circuit.

To install and service refrigerant circuits you need category 1 or 2. Refcom says a category 1 or 2 qualification is mandatory for its company certificate.

F gas courses: how to get qualified

You take an F gas course at a training centre approved by an awarding body. GOV.UK accepts personal qualifications from three organisations:

  • City & Guilds 2079: Level 2 Award in F Gas and ODS Regulations, in four pathways, Category I to IV. City & Guilds gives 31 December 2027 as the last registration date for 2079-11, so ask your centre what follows.
  • LCL Awards: Regulated Qualification in Fluorinated Greenhouse Gases on Refrigerant Systems (F-Gas Category I-IV). Categories I and II are Level 3, III and IV Level 2.
  • BESA: FG Cat 1 to FG Cat 4, delivered in BESA approved training centres.

What the assessment involves

The regulation requires a theory and a practical examination. All three bodies describe a multiple choice exam plus a practical assessment. LCL Awards says you need a good working knowledge of soldering and brazing.

Entry requirements, length and cost

  • Entry: for categories I and II, LCL Awards asks for a recognised qualification in refrigeration, heating and ventilation or a related sector, or 2 years’ auditable experience. Categories III and IV have none.
  • Length and cost: course providers set their own timetables and prices, so ask the training centre. The awarding bodies publish guided learning hours: City & Guilds lists 30 for Category I, and LCL Awards 31 for Category I and II, 7 for III and 14 for IV.
  • Renewal: LCL Awards refers to a five-year revalidation requirement, and Refcom to a five-year certification period for categories 1 and 2. GOV.UK’s qualifications page gives no expiry period, so check with your awarding body.

The F gas company certificate

GOV.UK says your company, including sole traders, must be certified by an approved body to install, repair, maintain or decommission stationary equipment containing F gas that others operate. For refrigeration, stationary air conditioning and heat pump systems it names three bodies: Refcom Certification Ltd, F-Gas Register (Quidos) and Bureau Veritas UK Ltd.

  • You must show that you employ enough trained staff, and have a written procedure for handling F gas safely and minimising emissions.
  • You must renew every 3 years.

It matters at the wholesaler too. GOV.UK says anyone selling F gas for this work must check the customer’s company certification and qualifications and record the certificate number. Buying F gas without them is against the law.

Heat pumps: split, monobloc and “hermetically sealed”

“Monobloc” is a trade term that the regulation does not define. The rules turn on two defined terms.

  • Hermetically sealed. GOV.UK’s wording: the part containing F gas is permanently sealed, for example welded or brazed shut, even if it has capped valves or service ports, with a tested leak rate under 3g per year.
  • Installation. The regulation’s wording: joining pieces of equipment or circuits that contain, or are designed to contain, F gas, where gas-carrying pipework is joined to complete a circuit, whether or not it then needs charging.

Split systems: you join refrigerant pipework on site. That is installation, so the engineer needs category 1 or 2 and the business needs a company certificate.

Sealed units: where the refrigerant circuit arrives factory sealed and you connect only water and power, you are not joining gas-carrying pipework. But GOV.UK does not set that out as an exemption. Servicing that breaks into the circuit, and recovering the gas at end of life, still need a qualified person. Ask a certification body before you rely on it.

Sellers follow the same line: only non-hermetically sealed equipment needs the installing technician’s details in writing before sale.

Leak checks and records

The equipment’s user is responsible for leak checks. Checks start at 5 tonnes of carbon dioxide equivalent, which GOV.UK’s table gives as 2.4kg of R-410A, and are due at least every 12 months. Hermetically sealed systems have no maximum period below 10 tonnes. From 5 tonnes, operators and service companies must keep records for 5 years.

Changes in 2025 and 2026

  • New single split systems holding under 3kg of F gas with a global warming potential above 750 have been banned since 2025. On 27 August 2026 GOV.UK added exceptions, including air to water single splits.
  • Defra consulted on a faster HFC phasedown. Its May 2026 update says it will not legislate in 2026 to change the steps from 1 January 2027.

For MCS, the Boiler Upgrade Scheme and the Level 3 heat pump award, see how to become a heat pump engineer.

Common mistakes

  • Assuming a gas qualification covers it. GOV.UK’s list of accepted qualifications does not mention Gas Safe registration. Our Gas Safe registration guide sets out what that covers.
  • Working as a sole trader on a personal qualification alone. GOV.UK says sole traders need the company certificate too.
  • Letting an unqualified mate do the pipework. Employers must make sure each employee holds the qualification for the work. Trainees must be enrolled on a course and supervised.

Penalties. GOV.UK says you could receive a civil penalty. In England and Scotland the 2015 Regulations set a maximum of £100,000 for an individual without the required certificate, a company without its certificate, or an employer whose staff are not qualified. The general maximum is £200,000. Intentional release is also a criminal offence.

Where ClearWorks fits

If you keep doing gas or electrical work alongside F gas work, ClearWorks is a certificate app for it: the landlord gas safety record, warning notice, service and breakdown records, EICR, EIC and minor works. It costs £15 per engineer a month for gas or for electrical, £24 for both, plus VAT, or £2.50 a certificate plus VAT on pay as you go, with your first 3 certificates free. See pricing.

In London we are also building a network of local gas engineers and electricians to take on landlord, servicing and repair work. No number of jobs is promised. Jobs for engineers

Sources: GOV.UK, Qualifications to work with F gas, updated 3 March 2026 (personal qualifications, categories, accepted bodies, vehicle, switchgear). GOV.UK, Company certification to work with F gas (sole traders, own equipment, certification bodies, 3-year renewal). GOV.UK, F gas guidance collection (types of F gas, regulators, Northern Ireland). GOV.UK, Fluorinated gases (79% phase down, HFC tables). GOV.UK, Selling F gas in cylinders or equipment (buyer checks, hermetically sealed wording). GOV.UK, Checking F gas equipment for leaks and Record F gas in equipment you own or service. GOV.UK, Bans on F gas in new products and equipment, updated 27 August 2026. GOV.UK, Amending the hydrofluorocarbon phasedown schedule, updated 15 May 2026 (HFC uses, 2027 phasedown steps). Regulation (EU) No 517/2014 as it applies in Great Britain (Articles 2, 3, 10 and 11). Commission Implementing Regulation (EU) 2015/2067 (Articles 2 to 6: categories, trainees, examinations, company certificates). The Fluorinated Greenhouse Gases Regulations 2015, SI 2015/310 (regulations 18, 29, 31 and 31A, Schedule 4). City & Guilds 2079, LCL Awards F-Gas Category I-IV and BESA refrigeration courses (qualification titles, assessment, entry, hours). Refcom, F-Gas qualifications and Refcom FAQs. Last checked 18 November 2026.

F gas qualification questions

Does Gas Safe registration cover F gas work?

No. F gas is refrigerant, not fuel gas. For air conditioning, heat pump and refrigeration systems, GOV.UK says you need a personal F gas qualification from City & Guilds, BESA or LCL Awards, or an equivalent that an EU member state recognises. Gas Safe registration is not on that list.

Which F gas category do I need for air conditioning and heat pumps?

Category 1 covers all activities on any size of system. Category 2 covers installing, maintaining, servicing and recovering refrigerant on systems with less than 3kg of F gas, or less than 6kg if hermetically sealed. Category 3 is recovery only and category 4 is leak checking without breaking into the circuit.

How long is an F gas course and what does it cost?

Course providers set their own timetables and prices, so ask the training centre. The awarding bodies publish guided learning hours: City & Guilds lists 30 hours for Category I, and LCL Awards lists 31 hours for Category I and II. Assessment is a multiple choice exam and a practical.

Do sole traders need an F gas company certificate?

Yes. GOV.UK says a company, including a sole trader, must be certified to install, repair, maintain or decommission stationary equipment containing F gas that others operate. It names Refcom, F-Gas Register (Quidos) and Bureau Veritas for air conditioning, heat pumps and refrigeration. The certificate is renewed every 3 years.

Does an F gas qualification expire?

The GOV.UK qualifications page does not give an expiry period. LCL Awards refers to a five-year revalidation requirement, and Refcom refers to a five-year certification period for categories 1 and 2. Check the date on your own certificate and ask your awarding body. The company certificate is separate and is renewed every 3 years.

Related pages

Certificates for your gas and electrical work

Your first 3 certificates are free. No card needed.

Founding London engineers keep their price for as long as they stay subscribed.

Get 3 free certificates