Guide for UK gas engineers.
Flue gas analyser: readings, ratio and BS 7967
A flue gas analyser samples combustion products and shows CO in ppm, CO2 and O2 in % and the CO/CO2 ratio, worked out as CO ÷ (CO2 × 10,000). The appliance manufacturer’s limits come first. Where none are given, TB 143 sets 350 ppm CO or less and a ratio of 0.0040 or less for commissioning new condensing boilers.
Last updated
What a flue gas analyser measures
A flue gas analyser draws a sample of the products of combustion through a probe and tells you how well the appliance is burning. Trade names vary: FGA, gas analyser, combustion analyser. Gas Safe Register’s bulletins call it an electronic combustion gas analyser (ECGA).
| Reading | Unit | What it tells you |
|---|---|---|
| Carbon monoxide (CO) | ppm | Product of incomplete combustion. Measured by a sensor. |
| Carbon dioxide (CO2) | % | How much of the sample is combustion product rather than air. |
| Oxygen (O2) | % | Excess air in the sample. Fresh air reads about 20.9%. |
| CO/CO2 ratio | none | CO compared with CO2. The main combustion performance figure. |
| Flue temperature | °C | Used with the inlet air temperature to give a nett temperature. |
| Efficiency | % | Calculated from the other readings and the fuel type. Not measured. |
Not every figure is measured. One manufacturer’s analyser measures CO2 with an infra-red sensor and calculates O2, the ratio, losses, excess air and efficiency. Others measure O2 and calculate CO2. Know which readings yours measures.
When engineers use one
BS 7967:2015 is the British Standard guide for using these analysers on domestic gas appliances. BSI’s published scope lists the uses:
- Commissioning. Confirming combustion where the appliance instructions ask for it.
- Servicing. Deciding how much servicing an appliance needs, and confirming combustion after service or maintenance.
- Investigating. Measuring carbon monoxide in the air of a dwelling, for example after a CO alarm.
It covers flueless, open-flue and room-sealed appliances, and any appliance where the manufacturer gives a sampling point. The same scope says an analyser is not a substitute for normal service and maintenance to the appliance instructions.
There is law behind the check. Regulation 26(9) of the Gas Safety (Installation and Use) Regulations 1998 lists what you must examine straight after working on an appliance. Since April 2018, where it is not reasonably practicable to examine operating pressure or heat input, you examine combustion performance instead.
Reading the CO/CO2 ratio
CO on its own can mislead, because air drawn into the sample dilutes it. The ratio corrects for that: dilution lowers CO and CO2 together, so the ratio stays the same.
The sum is measured CO in ppm, divided by CO2 in % multiplied by 10,000.
| CO (ppm) | CO2 (%) | Sum | Ratio |
|---|---|---|---|
| 60 | 9.0 | 60 ÷ (9.0 × 10,000) | 0.0007 |
| 400 | 9.0 | 400 ÷ (9.0 × 10,000) | 0.0044 |
Ratios are written to four decimal places. Check the zeros when you copy one down: 0.004 and 0.0004 are ten times apart.
Action levels: what counts as too high
The appliance manufacturer’s figure comes first. If the instructions give a CO or ratio limit, that is the limit for that appliance. General figures only apply where the manufacturer gives none.
- New condensing boilers. Gas Safe Register Technical Bulletin 143 (developed with HHIC, issued 26 March 2015) covers commissioning a condensing boiler with an air/gas ratio valve. Where the manufacturer gives no specific figures, its action levels are CO of 350 ppm or less and a ratio of 0.0040 or less. The check is made at maximum rate, then at minimum rate where the boiler allows. A manufacturer’s own CO figure may be lower than 350 ppm.
- Over the limit. TB 143 says not to adjust the air/gas ratio valve without first contacting the manufacturer’s technical helpline. If the readings cannot be brought within the limits, turn the boiler off and call the helpline. The boiler must not be commissioned until the fault is found and put right. If commissioning cannot be completed, the boiler must be disconnected from the gas supply.
- Scope. TB 143 is a commissioning procedure. It does not cover servicing or maintenance, where it points to the manufacturer’s instructions and BS 7967, or adjusting the air/gas ratio valve, where it points to TB 013.
- Fires, cookers and other appliances. BS 7967 gives the combustion performance action levels for other appliances. The standard is copyright, so take the figures from your own copy.
For background, a 2002 research report published by HSE, written to inform BS 7967, concluded that a ratio of 0.008 was a feasible “as-left” level for flued appliances, with some open-flue gas fires as an exception and cooker grills needing more work. It also said a manufacturer’s own criterion should always take precedence. That is history, not the current limit.
Common mistakes with a flue gas analyser
These points come from an analyser manufacturer’s manual. Yours may differ, so read it.
- Zeroing indoors or in the flue. Switch on and purge in fresh air. The analyser sets its zero from that air. After the purge, CO should read zero and O2 about 20.9%.
- Skipping the countdown. That analyser counts down for about 90 seconds before it is ready to use. An analyser stored somewhere cold may not read until it has warmed up.
- Wrong sampling point. Use the appliance’s sampling point. The probe tip belongs at the centre of the flue. On a balanced flue, push it far enough in that air cannot wash back over the probe.
- Leaks in the sample line. Oxygen too high and CO2 too low points to air getting into the probe, tubing or water trap.
- Full water trap or dirty filter. Check the trap every few minutes in use and the particle filter daily.
- Reading too soon. Wait for the readings to settle before you record them.
- Trusting the number alone. A good ratio does not replace a visual inspection of the appliance and flue.
Calibration and choosing an analyser
Calibration. One manufacturer’s manual says its analyser must have its calibration checked every year and be issued with a traceable certificate of calibration. It also recommends a regular check against test gas or a known source of combustion products, because a failed sensor can read zero. Follow your own analyser’s instructions and keep the certificate where you can show it.
Choosing one. Start with the standard the analyser is built to. BSI’s published scope for BS 7967:2015 covers analysers that conform to BS EN 50379-3, or to the older BS 7927:1998 as amended, which BS EN 50379-3 superseded on 1 March 2007. BS EN 50379-3:2012 sets performance requirements for portable analysers used in servicing gas-fired heating appliances.
Then check that it covers the fuels you work on, and that calibration and servicing are easy to arrange.
Recording the readings
Write the readings down while you are at the appliance. On commissioning a boiler, TB 143 says the CO level and ratio go on the Benchmark commissioning checklist. On a service, they go on the gas service record.
If the readings, or anything else you find, mean the appliance is unsafe and you cannot put it right, follow the current unsafe situations procedure and issue a gas warning notice.
In ClearWorks you enter the readings for each appliance and the combustion ratio is worked out for you. Readings outside limits are flagged as you type. Mark an appliance unsafe and the warning notice opens itself.
This page is a summary, not a procedure. Follow the appliance and analyser manufacturers’ instructions and the current edition of BS 7967. You remain responsible for the test and for the record. ClearWorks is not affiliated with Gas Safe Register, BSI, IGEM, HHIC or any analyser manufacturer.
Sources: BSI, BS 7967:2015 (published scope). BSI, BS EN 50379-3:2012 (published scope). Gas Safe Register Technical Bulletin 143, 26 March 2015 version (copy hosted by an installer; the controlled copy is in the Gas Safe Register engineers’ Technical Information area). Gas Safety (Installation and Use) Regulations 1998, regulation 26. HSE / Advantica report R5205, Combustion performance safety action levels for domestic gas appliances, March 2002. KANE455 analyser manual (cited as an example of manufacturer instructions, not a recommendation). Last checked 18 November 2026.
Flue gas analyser questions
What does a flue gas analyser measure?
It reads carbon monoxide in ppm, carbon dioxide and oxygen in %, and flue temperature, and works out the CO/CO2 ratio and the combustion efficiency. On some models the CO2 or the O2 figure is calculated from the other.
How is the CO/CO2 ratio calculated?
Divide the CO reading in ppm by the CO2 reading in % multiplied by 10,000. For example, 60 ppm of CO at 9.0% CO2 is 60 divided by 90,000, which is 0.0007.
What is a good CO/CO2 ratio for a boiler?
Use the boiler manufacturer’s figure first. Where the manufacturer gives none, Gas Safe Register Technical Bulletin 143 gives action levels for commissioning a new condensing boiler with an air/gas ratio valve: CO of 350 ppm or less and a ratio of 0.0040 or less.
How often does a flue gas analyser need calibrating?
Follow the analyser manufacturer’s instructions. As an example, one manufacturer’s manual requires the calibration to be checked every year and a traceable certificate of calibration to be issued.
What standard should a flue gas analyser meet?
BS 7967:2015 covers the use of analysers that conform to BS EN 50379-3, or to the older BS 7927:1998 as amended. BS EN 50379-3 sets the performance requirements for analysers used in servicing gas-fired heating appliances.