For Gas Safe engineers · By ClearWorks · Last updated 25 November 2026

Landlord gas safety certificate duties: the engineer's side

Under the Gas Safety (Installation and Use) Regulations 1998, the landlord holds the legal duty to arrange annual checks, deliver copies within 28 days and keep records. The Gas Safe engineer is responsible for competent regulation 26(9) testing, accurate defect reporting and issuing a complete regulation 36(3)(c) record.

Which duties sit with the engineer and which sit with the landlord?

Misunderstandings often happen when landlords or agents expect the engineer to chase access, decide tenancy start dates or determine whether a service substitutes for a safety check. Regulation 36 of GSIUR 1998 separates the duties clearly.

Division of responsibilities between Gas Safe engineer and landlord under GSIUR 1998
AreaEngineer's responsibilityLandlord's responsibility
Competence & registrationHold current Gas Safe registration and valid ACS categories for the applianceVerify the engineer is Gas Safe registered for the work
Inspection scopeCarry out all regulation 26(9) checks on every appliance and flueProvide access and list every landlord-owned appliance and flue
Record accuracyRecord all nine items required by regulation 36(3)(c) and issue the record on completionKeep each record until two further checks (or 2 years if removed)
Tenant deliverySend copies if the landlord agrees (for instance via certificate software)Ensure existing tenants get a copy within 28 days and new tenants before move-in
Unsafe appliancesFollow GIUSP, make safe with consent, attach labels and issue a warning noticeEnsure an unsafe appliance is not used and arrange remedial repairs

How does the regulation 36A two-month early check rule work?

Under regulation 36A of GSIUR 1998 (introduced by the 2018 Amendment Regulations and explained in HSE Approved Code of Practice L56), a landlord can have the annual check carried out up to two months before the expiry deadline and keep the original annual renewal date.

For engineers, this is helpful when booking seasonal workloads or following up no-access visits:

  • If the previous record expired on 15 November and you complete the check on 25 September (within two months), the next due date remains 15 November the following year.
  • To rely on regulation 36A, the landlord must retain records showing the check fell within the two-month window—meaning records are kept until two further checks have been completed.
  • Note that HSE L56 states there is no statutory requirement for the engineer to print the "next check due" date on the record, although doing so helps landlords and agents track compliance.

What happens if a tenant refuses access or a landlord asks you to backdate?

Engineers cannot force entry. Under HSE guidance for landlords and letting agents, the landlord must show they took all reasonable steps to comply and maintain a log of access attempts. Never issue or backdate a CP12 for an appliance you could not inspect.

If you gain access to inspect a boiler and hob in the kitchen, but a bedroom gas fire is locked off or capped and cannot be tested, record exactly which appliances were checked, which could not be tested, and why. Precision on the landlord gas safety record protects both you and the landlord.

Why does an annual boiler service not automatically satisfy regulation 36?

Landlords frequently book a "boiler service and gas cert" together, or assume an annual service sheet replaces a CP12. HSE landlord FAQs explicitly state that an annual service inspection does not automatically include every check required by a statutory safety check, nor does a safety check substitute for manufacturer-recommended maintenance.

In ClearWorks, engineers can issue both the CP12 record and the gas service record from the same property record, and send email and SMS reminders before the next renewal date so the repeat visit lands straight back in your diary.

Frequently asked questions

Who is responsible for giving the tenant a copy of the CP12?

The landlord has the legal duty to provide existing tenants with a copy within 28 days of the check and new tenants before they move in. With the landlord's agreement, an engineer or app can send the copy directly.

Does an engineer have to check a tenant's own gas cooker?

A landlord's statutory duty under regulation 36 covers appliances they provide, plus associated pipework. HSE recommends checking flues serving tenant-owned appliances too, and noting ownership clearly on the record.

How long must landlord gas safety records be kept?

Landlords must keep each record until two further checks of that appliance or flue have taken place, or for 2 years from the last check if the appliance or flue is removed.

What does ClearWorks cost for Gas Safe engineers?

The Gas plan is £15 per engineer a month plus VAT for unlimited certificates (£150 a year + VAT on annual billing), or £2.50 per certificate plus VAT on pay as you go. Every engineer gets 3 free certificates with no card needed.

Related pages

Sources: Gas Safety (Installation and Use) Regulations 1998, regulation 36; regulation 36A; regulation 26(9); HSE, L56 Approved Code of Practice (fifth edition); HSE, Gas safety: landlords and letting agents FAQs; HSE, Gas safety checks: what needs them?. Last checked 25 November 2026. This article is a practical summary for engineers and electricians, not legal advice or a substitute for BS 7671, GSIUR 1998 or Gas Safe guidance. ClearWorks is not affiliated with or endorsed by Gas Safe Register, HSE, the IET, Electrical Safety First, NICEIC or NAPIT.