For landlords and letting agents in England, and the engineers they use. Last checked 18 November 2026.
Gas and electrical safety certificates for landlords
A rented home with gas needs a gas safety record every 12 months and an electrical report at least every 5 years. This guide puts the two side by side: which law, who can sign, when the tenant gets a copy and what happens after a bad result.
Last updated
The two certificates side by side
A rented home in England with gas needs two separate safety documents. They come from different laws, run on different clocks and are signed by different trades. One does not cover the other.
| Certificate | Law | How often | Who can do it | Copy to tenant | Keep for |
|---|---|---|---|---|---|
| Gas safety record (often called a CP12) | Gas Safety (Installation and Use) Regulations 1998, regulation 36 | Every 12 months at most, for each appliance and flue the landlord provides | A Gas Safe registered engineer | Sitting tenants: within 28 days of the check. New tenants: before they move in | Until two more checks have been done. HSE puts that at two years or more |
| Electrical report (usually an EICR) | Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020, regulation 3 | Every 5 years at most, or by the earlier date the last report sets | A qualified person: someone competent to inspect and test to BS 7671 | Sitting tenants: within 28 days of the inspection. New tenants: before they move in | Until the next inspection is due or done, whichever is later. Then pass it to the next inspector |
The electrical rules add two more deadlines. A prospective tenant who asks in writing gets the report within 28 days. The local council gets it within 7 days of a written request.
The forms have their own pages: the gas safety record, the EICR and what an EICR costs.
What the names mean in law
Neither law calls its document a certificate. People ask for a gas and electric certificate, gas and electricity certificates or landlord safety certificates. They mean these two documents.
- Gas safety certificate. The law asks for a record of the yearly safety check. HSE calls it the landlord gas safety record and notes that Gas Safe Register does not produce a form of its own.
- Electrical safety certificate. The law asks for a report giving the results and the date of the next inspection. GOV.UK says this is usually an Electrical Installation Condition Report.
- BS 7671 electrical safety certificate. BS 7671 is the standard, not the document. The regulations define the electrical safety standards as the 18th edition of the Wiring Regulations, BS 7671. The EICR is the report that says whether the home meets it. See our Amendment 4 guide and the EICR template.
An Energy Performance Certificate is a third, unrelated document. It rates energy efficiency from A to G and GOV.UK says you must have one when renting out a property. It says nothing about gas or electrical safety.
Two clocks that run separately
Gas runs yearly. Electrics run five-yearly. Agents who track them on one renewal date get caught out.
- Gas can be done early. A check completed in the 2 months before the deadline counts as done on the deadline, so the anniversary does not drift (regulation 36A, added in 2018).
- Gas before a new let. Each appliance and flue must have been checked in the 12 months before the lease starts. HSE says an empty property still needs an up to date record ready for the next tenant.
- Electrics have no early-renewal rule. The next inspection is due by the date on the report, which can be no more than 5 years after the last one.
- Electrics before a new let. The regulations call for inspection and testing before the tenancy starts. GOV.UK guidance says a report under 5 years old with no work outstanding does not need repeating: give the new tenant a copy. It recommends a visual check between tenancies.
When the result is not clean
Electrical. GOV.UK guidance says a report with any C1 or C2 code will state the installation is unsatisfactory, and remedial work is then required. Where the inspector asks for further investigation (FI), that must be done too. C3 is a recommendation only.
The landlord then has to:
- Get the work done by a qualified person within 28 days of the inspection, or sooner if the report says so.
- Get written confirmation that the work is done. GOV.UK accepts a satisfactory EICR, an Electrical Installation Certificate or a minor works certificate.
- Send that confirmation, with the original report, to each tenant and the local council within 28 days of the work being finished.
Local councils enforce this. They can serve a remedial notice, arrange the work themselves and recover the cost, and impose a financial penalty of up to £40,000.
Gas. The law sets no pass or fail. The record must list any safety defect found and any remedial action taken. HSE says the record should be issued when the check is finished, not held back until repairs are done. The landlord must then take remedial action and make sure an unsafe appliance is not used.
Common mistakes
- Treating one as covering the other. A gas engineer’s record says nothing about the wiring, and an EICR says nothing about the boiler.
- Using an appliance test as the electrical report. The report is about the fixed installation: wiring, sockets, light fittings and the consumer unit. A portable appliance test does not replace it. The five-yearly equipment check in the regulations applies to social landlords who supply equipment.
- Assuming any installation certificate will do. GOV.UK says an Electrical Installation Certificate stands in for the report for 5 years where a home is newly built or completely rewired. A certificate that covers only part of the installation does not.
- Re-letting on an out-of-date gas record. The check must be in date before the new lease starts, and the new tenant must be given the record before moving in.
- No proof of delivery. Both laws set a deadline for giving the tenant a copy. HSE allows an electronic gas record if the tenant agrees and can open it, with a paper copy on request.
- Giving up when a tenant refuses access. Under both sets of rules the landlord has to show all reasonable steps were taken. Keep every letter and message.
- Forgetting the alarms. Separate rules in England require a smoke alarm on each storey with living accommodation and a carbon monoxide alarm in any room used as living accommodation that has a fixed combustion appliance other than a gas cooker. See the fire alarm certificate guide and, for larger buildings, emergency lighting.
Checking the person who signs
Gas. HSE advises landlords to check the back of the engineer’s Gas Safe Register card, which shows the types of gas work they are competent to do, or to look up the engineer or business on the Gas Safe Register website. A registered engineer must not sign off gas work done by someone unregistered.
Electrical. There is no single card. The regulations define a qualified person as someone competent to do the inspection and testing, and any further work, to the electrical safety standards. GOV.UK points landlords to the Registered Competent Person Electrical register and Electrical Safety First’s find-an-electrician tool.
Outside England: the gas regulations extend to England, Wales and Scotland. The 2020 electrical regulations apply in England only. Wales has its own rules: an electrical test every five years, with different deadlines for giving the contract-holder a copy.
For engineers who do both
Landlords and agents want both documents on time and proof the tenant received them. ClearWorks is an app for the engineer who issues them.
- Gas safety records and EICRs from the same app, on your phone, with no signal needed.
- Sent to the landlord, agent and tenant when you sign, with a record of when each one opened it.
- Reminders to the landlord by email and text before the next one is due.
- £15 per engineer a month for gas or for electrical, £24 for both, plus VAT. Your first 3 certificates are free.
Letting agent or landlord? Certificates issued in ClearWorks carry a QR code you can scan to check one was issued and is in date. ClearWorks does not carry out inspections.
See pricing · Landlord jobs for engineers
This page is a summary for general information, last checked 18 November 2026. It is not legal advice and it focuses on England. Landlords should read the regulations and official guidance or take advice. Engineers must work to the current regulations and standards and remain responsible for their inspections and certificates. ClearWorks is independent and is not affiliated with or endorsed by Gas Safe Register, HSE or GOV.UK.
Sources: Gas Safety (Installation and Use) Regulations 1998, regulation 36 and regulation 36A; HSE: landlords’ responsibility for gas safety and gas safety check records; Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020; GOV.UK: electrical safety standards guidance; GOV.UK: your landlord’s safety responsibilities; Smoke and Carbon Monoxide Alarm (England) Regulations 2015 and GOV.UK alarm guidance; GOV.UK: Energy Performance Certificates; Welsh Government: fitness for human habitation guidance. Last checked 18 November 2026.
Gas and electrical certificate questions
Do I need both a gas and an electrical safety certificate to rent out a home?
In England, a landlord who provides gas appliances or flues needs a gas safety record from a check done at least every 12 months. Separately, the electrical installation must be inspected and tested at least every 5 years, with a report. A home with no gas appliances has no annual gas check, but HSE says any gas pipework must still be kept safe.
Can one engineer issue both certificates?
Only if that person is Gas Safe registered for the gas work and is also competent to inspect and test electrical installations to BS 7671. They are separate checks under separate laws, and each document has to be signed by someone entitled to do that check.
How long do the two certificates last?
A gas safety check must be repeated within 12 months. An electrical report sets its own next inspection date, which can be no more than 5 years away and can be sooner.
What is the penalty for not having an electrical safety report?
In England, the local council can impose a financial penalty of up to £40,000 on a landlord who breaches the duties in the electrical safety regulations. The council can also serve a remedial notice and recover the cost of work it arranges.
Is a BS 7671 electrical safety certificate the same as an EICR?
People use the phrase for the EICR. BS 7671 is the wiring standard the installation is inspected against. The document a landlord in England needs is the report of that inspection, which is usually an Electrical Installation Condition Report.
Related pages
Engineers: issue gas and electrical certificates in ClearWorks
Your first 3 certificates are free. No card needed.
Founding London engineers keep their price for as long as they stay subscribed.