PAT testing: what it is, the law and how often
PAT testing is the inspection and testing of electrical appliances to make sure they are safe to use. The law asks for equipment to be maintained. It does not name PAT or set a yearly test. This page sets out what HSE and GOV.UK say.
Last updated
What is PAT testing?
PAT stands for portable appliance testing. The Health and Safety Executive (HSE) uses the term for the examination of electrical appliances and equipment to make sure they are safe to use.
HSE says most electrical safety defects can be found by looking, and some can only be found by testing. The two work together.
HSE’s leaflet INDG236 describes a portable or movable appliance as any item that can be moved, whether it is connected to the supply or not. It usually has a lead and a plug. Kettles, vacuum cleaners, fridges, desktop computers and extension leads all count. A large wired-in item that is not designed to be moved, such as a water boiler, falls under fixed installation maintenance instead.
This page is a summary for general information. It is not legal advice and it is not the HSE guidance or the IET Code of Practice. Employers and landlords should read the official guidance for their own situation. Anyone inspecting or testing equipment must be competent, must follow the current guidance and the manufacturer’s instructions, and remains responsible for the work.
Is PAT testing a legal requirement?
Not by name. The duty comes from regulation 4(2) of the Electricity at Work Regulations 1989. Where it is necessary to prevent danger, all systems must be maintained so as to prevent that danger, so far as is reasonably practicable.
HSE spells out what that does and does not mean:
- The regulations do not say what must be done, by whom or how often.
- They do not make inspection or testing of appliances a legal requirement, and they do not require it every year.
- Asked whether PAT is compulsory, HSE answers “No”. The law requires an employer to make sure electrical equipment is maintained to prevent danger.
INDG236 says the duty covers equipment employees use at work, whether it is their own or supplied by the employer.
User checks, visual inspection and testing
HSE describes three levels of attention. Which ones an item needs depends on the risk.
User checks. The person using the equipment looks it over before use, with it disconnected. INDG236 lists what to look for:
- damage to the lead, such as fraying, cuts or heavy scuffing
- a damaged plug cover or bent pins
- coloured wires showing where the lead enters the plug
- damage to the outer cover of the equipment, or loose parts or screws
- signs of overheating, such as burn marks or staining
Formal visual inspection. A more thorough look at set intervals. It also asks whether the equipment suits the job and is used as the manufacturer intends.
Combined inspection and testing. This is the portable appliance test itself. INDG236 recommends it for earthed (Class I) equipment, to confirm the earth connection is sound. Double insulated (Class II) equipment does not need the test, HSE says, but still needs user checks and visual inspection. If the Class II symbol is missing, HSE says to treat the item as Class I.
A test only shows the state of the appliance at the time it was done. HSE says user checks should carry on afterwards.
How often should PAT testing be done?
Workplace law sets no fixed interval. HSE says the frequency depends on the type of equipment and where it is used. Social landlords in England have a 5-year rule, covered below.
For low-risk places such as offices, shops, some parts of hotels and residential care homes, INDG236 suggests starting points.
| Equipment | User checks | Formal visual inspection | Combined inspection and testing |
|---|---|---|---|
| Battery-operated (under 40 volts) | No | No | No |
| Extra low voltage (under 50 volts AC), such as telephone equipment | No | No | No |
| Desktop computers and screens | No | Yes, 2 to 4 years | No if double insulated, otherwise up to 5 years |
| Photocopiers and fax machines, rarely moved | No | Yes, 2 to 4 years | No if double insulated, otherwise up to 5 years |
| Class II, not hand-held, moved occasionally, such as fans and table lamps | No | Yes, 2 to 4 years | No |
| Class II, hand-held, such as some floor cleaners | Yes | Yes, 6 months to 1 year | No |
| Class I, such as electric kettles and irons | Yes | Yes, 6 months to 1 year | Yes, 1 to 2 years |
| Leads, plugs, mains extension leads and battery-charging equipment | Yes | Yes, 6 months to 4 years, depending on the equipment it is connected to | Yes, 1 to 5 years, depending on the equipment it is connected to |
Where items are tested together as a group, HSE says to use the shortest interval in the group. Higher-risk workplaces are covered by HSE’s fuller guide, HSG107.
Who can carry out PAT testing?
HSE’s test is competence, not job title. In many low-risk environments a sensible member of staff can do visual inspections if they have enough knowledge and training. HSE says you do not need to be an electrician for that.
Combined inspection and testing asks for more: the right equipment, the ability to use it properly and the ability to understand the results. INDG236 adds that the test does not have to be done by an electrician.
For practitioners, HSG107 points to the IET’s Code of Practice for In-service Inspection and Testing of Electrical Equipment.
Is there a PAT testing certificate?
Workplace law does not ask for one. HSE says there is no legal requirement to label equipment that has been inspected or tested, and no requirement to keep records. It adds that either can help to monitor a maintenance scheme and show that one exists.
A “PAT certificate” from a contractor is a record of what was checked. It is not a statutory form. HSG107 makes one point about labels: if a label is applied, it should not carry a next test due date. When the next test is due is for the dutyholder to decide, based on risk.
PAT testing for landlords in England
The rules for rented homes in England are set out in GOV.UK’s guidance on the Electrical Safety Standards regulations, which were extended to social housing in 2025.
All landlords. The electrical installation must be inspected and tested by a qualified person at least every 5 years. GOV.UK describes this as the “fixed” electrical parts: the wiring, socket-outlets, light fittings and consumer unit, plus permanently connected equipment such as showers and extractors. The report is usually an EICR. See what happens during EICR testing, which electrical safety certificate is which and EICR cost.
Social landlords. The guidance adds a duty for electrical equipment the landlord provides under the tenancy. GOV.UK gives cookers, fridges and microwaves as examples. A qualified person must check each item at least every 5 years, or sooner if the last record sets an earlier date. The check is a visual inspection, testing or both, as that person considers necessary. In the regulations this duty sits in regulation 3B and falls on registered providers. For tenancies granted before 1 December 2025, GOV.UK says the first check had to be done before 1 November 2026.
The landlord gets an In-service Inspection and Testing of Electrical Equipment (ISIT) record. GOV.UK says it may include details of the equipment, its condition, notes on the environment it is used in, and the results. Where the equipment is safe for continued use, it also sets a date for the next check.
GOV.UK also says tenants are responsible for the safety of their own electrical equipment.
For electricians: the fixed installation in ClearWorks
ClearWorks is an app for electricians.
- Issue the EICR, the EIC and the minor works certificate, all to BS 7671:2018+A4:2026.
- Turn EICR findings into a quote, fix them, then issue the linked minor works certificate.
- Missing details and readings outside limits are flagged as you fill the form in.
The electrical plan is £15 per engineer a month + VAT. Pay as you go is £2.50 a certificate + VAT. Your first 3 certificates are free. See EICR software for electricians and pricing.
Sources: HSE, PAT – Portable appliance testing FAQs (definition, no legal requirement to test, records and labels, competence). HSE, INDG236(rev3) Maintaining portable electric equipment in low-risk environments (what counts as portable, user checks, Class I and II, Table 1 intervals). HSE, HSG107 Maintaining portable electrical equipment, third edition (labels, IET Code of Practice). Electricity at Work Regulations 1989, regulation 4. GOV.UK, Electrical safety standards in the private and social rented sectors: guidance (installations, equipment checks, ISIT record). Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020, regulation 3B.
Last checked 18 November 2026. ClearWorks is independent and is not affiliated with or endorsed by HSE, the IET or any government body.
PAT testing questions
What is PAT testing?
PAT stands for portable appliance testing. HSE uses the term for the examination of electrical appliances and equipment to make sure they are safe to use. It combines visual examination with testing, because some defects show only on inspection and others only on test.
Is PAT testing a legal requirement?
Not as such. The Electricity at Work Regulations 1989 require electrical equipment that could cause danger to be maintained. HSE says the regulations do not make inspection or testing of appliances a legal requirement and do not require it every year.
How often should PAT testing be done?
At work, the law sets no interval. HSE says it depends on the type of equipment and where it is used. For low-risk places, HSE leaflet INDG236 suggests initial intervals, for example a combined inspection and test every 1 to 2 years for earthed equipment such as electric kettles. Social landlords in England must have the equipment they provide checked at least every 5 years.
Do I need a PAT testing certificate?
At work, HSE says there is no legal requirement to keep records of inspection or testing, or to label equipment. It says records and labels can be useful for managing a maintenance scheme and showing that one exists. Social landlords in England must get a record of each equipment check, GOV.UK says.
Who can do PAT testing?
HSE says the person must be competent. A trained member of staff can do visual inspections in many low-risk environments. Combined inspection and testing needs more knowledge and experience, the right equipment and the ability to understand the results. HSE says it does not have to be an electrician.
Do landlords need PAT testing in England?
GOV.UK guidance says all landlords must have the electrical installation inspected and tested at least every 5 years. It says social landlords must also have electrical equipment they provide under the tenancy checked by a qualified person at least every 5 years.
Does new equipment need a PAT test?
At work, HSE says new equipment should be supplied in a safe condition and should not need a formal portable appliance inspection or test. It recommends a simple visual check to confirm the item is not damaged.