For landlords, homeowners and the electricians they use. Last checked 18 November 2026.
Electrical safety certificate: which document do you need?
No document is legally called an electrical safety certificate. A landlord usually means an EICR. Someone who has had work done usually means an installation or minor works certificate. This page shows which one fits and how long it lasts.
Last updated
No form carries that name
“Electrical safety certificate” is an everyday phrase, not a document title. The landlord regulations in England ask for a “report”. The IET’s model forms for BS 7671, the wiring standard, are an Electrical Installation Condition Report, an Electrical Installation Certificate and a Minor Electrical Installation Works Certificate. So the first job is to work out which of the three someone is asking you for.
| Your situation | The document | Where that comes from |
|---|---|---|
| Letting a home in England | A report of inspection and testing, usually an EICR | The 2020 electrical safety regulations, regulation 3 |
| Letting a home in Wales or Scotland | An EICR, under each nation’s own rules | See Wales and Scotland below |
| A new installation, a new circuit or a replacement consumer unit | An Electrical Installation Certificate (EIC) | Notes on the IET model EIC |
| Small work that adds no new circuit | A minor works certificate | Heading of the IET model minor works form |
| Living in a home you own | Nothing under the landlord regulations. A periodic inspection is recommended | Regulation 1 limits those regulations to tenancies |
This page is a summary for general information. It is not legal advice and it is not the standard. Landlords should read the regulations and official guidance for their nation. Electricians must work to the current BS 7671 and their scheme’s rules, and remain responsible for the inspection, the testing and whatever they sign.
Landlord electrical safety certificate in England
The law is the Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020. They started as private-sector rules, and GOV.UK says they were updated in 2025 to take in social housing. Regulation 3 is where the duties sit. A landlord has to:
- Have the installation inspected and tested by a qualified person at intervals of no more than 5 years, and before a tenancy begins (an in-date report can cover a new let, see below). The regulation defines a qualified person as someone competent to do that inspection and testing, and any follow-up work, to the electrical safety standards.
- Get a report from that person. It must give the results and the date by which the next inspection and test is required.
- Give copies to each existing tenant within 28 days of the inspection, to a new tenant before they move in, to a prospective tenant within 28 days of a written request, and to the local housing authority within 7 days of a written request.
- Keep a copy and give it to whoever carries out the next inspection.
GOV.UK’s guidance says the report is “usually an Electrical Installation Condition Report”. That is why agents ask for an EICR when they say landlord electrical safety certificate.
If the home has gas as well, the gas and electrical safety certificates guide sets the two regimes side by side, with enforcement and penalties.
How long an electrical safety certificate is valid
An EICR has no fixed life printed on it. The inspector recommends a date for the next inspection, and the guidance for recipients on the IET model form says to look for it in Section F. The law then sets a ceiling for rented homes.
- Rented home in England. The next inspection is due within 5 years, or by the earlier date if the report gives one.
- Between tenancies. GOV.UK says a fresh inspection is not needed for a new let when the last one was under 5 years ago and the report calls for no further work. The landlord gives the incoming tenant the existing report. A visual check first is recommended.
- New build or full rewire. GOV.UK says the EIC can be given to tenants in place of a report, and no further inspection is needed for 5 years from its issue, as long as the landlord has met the other duties in the regulations.
- Owner-occupied home. Nothing in the landlord regulations sets a date. The charity Electrical Safety First recommends an inspection every 10 years.
For prices, see what an EICR costs.
Satisfactory or unsatisfactory
An EICR does not say pass or fail. The IET model report gives an overall assessment of Satisfactory or Unsatisfactory, and each observation gets a code.
- C1 and C2. Danger present (C1) and potentially dangerous (C2). The form says an unsatisfactory assessment means one or both have been found.
- C3. Improvement recommended. The form treats it as advisory.
- FI. Further investigation. On the Amendment 4 form this is advisory too, and does not change the overall assessment.
For a landlord in England the duty goes further than the form. GOV.UK says C1 or C2 means remedial work is required, that a landlord must also make sure any FI is carried out, and that C3 improvements are optional. Under regulation 3 the work has to be done by a qualified person within 28 days of the inspection, or within the shorter period the report gives. The landlord then gets written confirmation and sends it, with the report, to each tenant and the local housing authority within 28 days of the work being completed.
GOV.UK lists a satisfactory EICR, an EIC and a minor works certificate as acceptable confirmation. For the codes in detail, see the EICR page and the Amendment 4 guide.
Certificates for new electrical work
The EICR’s own notes say it is only for reporting on an installation that already exists. Work that has just been done is certified on a different form.
- EIC. For a new installation, an addition or alteration that brings in one or more new circuits, or a replacement consumer unit or distribution board.
- Minor works certificate. The model form is headed for use only where no new circuit is provided.
In England there is a second layer. Regulation 12(6A) of the Building Regulations 2010 makes Part P electrical work notifiable when it installs a new circuit, replaces a consumer unit, or adds to or alters a circuit in a special location such as the space around a bath or shower. Our Electrical Installation Certificate guide covers how notification works, who signs, and which papers a seller is asked for.
Wales and Scotland
The 2020 regulations apply in England only.
Wales. Regulation 6 of the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 requires a valid electrical condition report during each period of occupation. It is valid for 5 years from the inspection, or until an earlier date the report sets. The contract-holder gets a copy within 14 days of the occupation date. Welsh Government guidance says an EICR meets the definition.
Scotland. The Scottish Government’s Repairing Standard guidance for private landlords calls for an electrical safety inspection before a property is first let and then at intervals of no more than five years. It covers the installation, recorded on an EICR, and electrical equipment as well. The landlord keeps the EICR for six years and gives the most recent one to a new tenant before the tenancy starts.
Northern Ireland is outside the scope of this page.
For electricians: the EICR in ClearWorks
ClearWorks is an app for the electricians who issue these documents.
- EICR to BS 7671:2018+A4:2026. Observations coded C1 to FI, with Zs checked against the protective device.
- The assessment follows your codes. A C1 or C2 makes the report Unsatisfactory.
- Minor works certificate. Linked to the EICR findings it fixes.
- Sent when you sign. To the landlord, agent and tenant, with reminders before the next one is due.
- Works with no signal. It saves on the phone and sends when you are back online.
The electrical plan is £15 per engineer a month + VAT. Pay as you go is £2.50 a certificate + VAT. Your first 3 certificates are free.
See EICR software for electricians
Sources: Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020, regulation 3 (5 years, qualified person, report, 28-day and 7-day deadlines, remedial work, written confirmation) and regulation 1 (England only, tenancies). GOV.UK, Electrical safety standards in the private and social rented sectors: guidance (usually an EICR, codes, new builds, re-letting, acceptable confirmation). IET, BS 7671 model forms: EICR, EIC and minor works for BS 7671:2018+A4:2026. Building Regulations 2010, regulation 12. Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022, regulation 6 and Welsh Government guidance for landlords. Scottish Government, Repairing Standard statutory guidance for private landlords, Annex D3. Electrical Safety First, periodic inspection explained.
Last checked 18 November 2026. ClearWorks is independent and is not affiliated with or endorsed by the IET, BSI, NICEIC, NAPIT, Electrical Safety First or any government body.
Electrical safety certificate questions
Is there a document called an electrical safety certificate?
Not by that name. The landlord regulations in England ask for a report of inspection and testing, which is usually an Electrical Installation Condition Report. New work is certified on an Electrical Installation Certificate or a Minor Electrical Installation Works Certificate.
What electrical safety certificate does a landlord need in England?
A report from a qualified person who has inspected and tested the electrical installation, giving the results and the date the next inspection is due. GOV.UK guidance says this is usually an EICR. It must be repeated at intervals of no more than 5 years.
How long is an electrical safety certificate valid?
For a rented home in England, until the date the report gives for the next inspection, which can be no more than 5 years away. Wales also uses 5 years, or an earlier date set by the report. For an owner-occupied home, Electrical Safety First recommends an inspection every 10 years.
Do homeowners need an electrical safety certificate?
The landlord regulations in England apply to tenancies, so they place no duty on someone living in a home they own. Electrical Safety First recommends that an owner-occupied home is inspected and tested every 10 years.
Does a certificate for new work count for a landlord?
GOV.UK guidance says that where a home is newly built or has been completely rewired, the landlord can give tenants the Electrical Installation Certificate, and no further inspection is needed for 5 years after it was issued, as long as the landlord has met the other duties in the regulations.
Which electrical documents can an electrician issue in ClearWorks?
The EICR, the EIC and the minor works certificate, all to BS 7671:2018+A4:2026.
Related pages
Electricians: do your next landlord EICR in ClearWorks
Your first 3 certificates are free. No card needed.
Founding London engineers keep their price for as long as they stay subscribed.