Guide for gas engineers, landlords and homeowners.

Boiler service checklist: what a service includes

A boiler service covers whatever the manufacturer’s servicing instructions set for that model. Where those are missing, HSE’s minimum is to examine the appliance, pipework, ventilation and flue, carry out performance tests and put right what needs it. Manuals recommend at least once a year. A service is not a landlord gas safety check.

Last updated

What counts as a boiler service

There is no single national list. A boiler service is whatever the manufacturer’s installation and servicing instructions say it is for that model. Where those instructions are missing, HSE sets a minimum: examine the physical condition and safe working of the appliance, pipework, ventilation and flue, carry out performance tests, and put right what needs it. HSE also says anyone employed to work on gas appliances in a home must be Gas Safe registered and competent in that type of work.

Two current combi manuals, from Manufacturer A and Manufacturer B, both test first and let the results decide how far the boiler is opened up.

  • Manufacturer A says the extent of the service work is set by the operating condition of the appliance when tested.
  • Manufacturer B has the engineer take a combustion reading first. Above a CO/CO2 ratio of 0.004 the schedule goes to the full cleaning procedure: burner and fan out, heat exchanger flushed, electrode cleaned. Below it, the schedule goes to a shorter check procedure.

So a service where the burner stays in place can be exactly what the manual asks for.

Boiler service checklist

A summary of the annual checks in Manufacturer A’s manual. It is one boiler. Use the schedule for the appliance in front of you.

Boiler service checklist: what one manufacturer’s manual asks for (summary)
CheckWhat it involves
Operation and fault historyRun heating and hot water, note anything irregular and read the stored faults.
Visual inspection, outsideThe appliance, system and components still comply. Clearances are kept if the boiler is in a cupboard.
Visual inspection, insideCasing off: signs of leaking, corrosion or distress. Water joints that weep are remade.
Gas leakageGas valve, gas joints and test points checked with a sniffer or analyser at every annual visit. A leaking gas valve is replaced, not repaired.
Heat exchangerFan pressure test. Clean the heat exchanger only if the reading says so, then check the electrodes and replace disturbed gaskets.
CondensateDrain not obstructed. Siphon cleaned and refilled.
Gas supplyWorking inlet pressure at maximum output, then the gas rate at the meter.
CombustionFlue gas analysis at maximum and minimum output.
FlueJoints secure, terminal and guard clear and undamaged, then the flue integrity reading.
Safety devicesFlame failure check. If the system keeps losing pressure, the pressure relief valve, the system and the expansion vessel are checked.
System waterInhibitor concentration checked every 12 months.
FinishCasing refitted, boiler left on the customer’s settings, paperwork updated.

The same manual says service work must not be attempted without a calibrated CO/CO2 analyser and a manometer.

The readings behind the ticks

Gas rate and pressure. Manufacturer A says not to carry on with the other checks if the right inlet pressure cannot be reached at maximum output. Time the meter and convert it with the gas rate calculator.

Combustion. Limits are specific to the boiler. As an example, Manufacturer A’s manual asks for CO below 250 ppm, and on natural gas CO2 between 9.0% and 9.8% at maximum output, measured 10 minutes after firing. If CO2 is still out after the listed checks, it says to phone the manufacturer’s helpline before adjusting the gas valve. The flue gas analyser guide explains the ratio, and the general commissioning figures that apply where a manufacturer gives none.

Gas tightness. Both manuals call for a gas tightness check after work on gas-carrying parts. Manufacturer A’s manual names a gas sniffer or analyser for it. The full tightness test for an installation is covered in the gas tightness test guide.

System water. The Benchmark service record says an inhibitor test is required at every annual service, in line with the manufacturer’s instructions and BS 7593.

What gets written down

Both manuals tell the engineer to complete the Benchmark service record in the manual after each service. In Manufacturer A’s copy, each entry has space for:

  • the date, and whether the visit was a service or interim work
  • engineer name, company, phone number and Gas Safe registration number
  • CO in ppm, CO2 in % and the CO/CO2 ratio, at maximum and at minimum rate
  • whether a flue integrity check was done, where possible
  • the gas rate, in m³/h or ft³/h
  • whether the inhibitor concentration was checked and acted on
  • any parts fitted, comments and a signature

That page stays in the manual with the boiler. The customer’s own record of the visit is the engineer’s gas service record. Those two documents show what was done. A new boiler has a separate boiler commissioning checklist, filled in once at installation.

A service is not a landlord gas safety check

Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 makes a landlord have each gas appliance and flue they provide checked for safety at intervals of not more than 12 months, and keep a record. The check must cover at least the four matters in regulation 26(9): the flue, the supply of combustion air, operating pressure or heat input (or combustion performance where those cannot reasonably be examined), and safe functioning.

A service is maintenance on one appliance, to its manual. HSE tells landlords not to assume an annual service covers the points a safety check needs, or that a safety check alone is enough maintenance.

Many engineers do both in one visit and issue two documents: the service record and the landlord gas safety record (CP12).

How often a boiler should be serviced

HSE says to service gas appliances and flues in line with the manufacturer’s instructions, and annually where those are not available unless a Gas Safe registered engineer advises otherwise. Both manuals recommend at least once a year.

Guarantees are stricter. Terms differ by product, so read your own.

  • Manufacturer A (June 2023 edition): serviced annually, with details in the service record and available for inspection on request.
  • Manufacturer B (warranty terms): serviced by a Gas Safe registered engineer at the end of each 12 month period, or the warranty lapses.
  • Manufacturer C (domestic boiler guarantee): serviced annually to the manufacturer’s instructions, with details recorded in the Benchmark logbook.

For what engineers charge, see our guide to boiler service cost.

If the service finds something unsafe

Under regulation 34, an engineer who knows or suspects an appliance cannot be used without danger must take all reasonably practicable steps to tell the responsible person straight away.

Engineers classify what they find with the Gas Industry Unsafe Situations Procedure, published by IGEM as IGEM/G/11. It has two categories, Immediately Dangerous and At Risk. HSE says both carry the same label: “Danger Do Not Use”. The customer is given a gas warning notice.

Doing the service record on ClearWorks

Engineers fill in the service record on their phone at the boiler and send it before they leave.

  • Readings outside limits are flagged as you type
  • The combustion ratio is worked out for you
  • Mark an appliance unsafe and the warning notice opens
  • Reminders go out before the next service is due
  • Works with no signal and sends when you are back online

The gas plan is £15 per engineer a month + VAT. Pay as you go is £2.50 a certificate + VAT. Your first 3 certificates are free.

See the gas service record

This page is a summary, not a servicing procedure. Follow the manufacturer’s instructions for the appliance and the current regulations and standards. The engineer remains responsible for the service, the readings and the record. ClearWorks is not affiliated with Gas Safe Register, IGEM, HHIC, the Benchmark scheme or any boiler manufacturer.

Sources: Manufacturer A: Worcester Bosch Greenstar 4000 installation and maintenance instructions, 6 720 891 161 (2021/10), including its Benchmark service record pages. Manufacturer B: Ideal Logic Max Combi2 installation and servicing manual, Republic of Ireland edition, UIN 237668 A05 (11/2024). Benchmark scheme, What is Benchmark? Worcester Bosch guarantee terms, June 2023 edition. Ideal Heating Max Confidence warranty terms. Manufacturer C: Vaillant domestic boiler guarantee terms. HSE, Maintenance: gas appliances and flues and Domestic gas: frequently asked questions. Gas Safety (Installation and Use) Regulations 1998, regulation 26, regulation 34 and regulation 36. IGEM, IGEM/G/11 Edition 2 with amendments to July 2025. Last checked 18 November 2026.

Boiler service questions

What does a boiler service include?

Whatever the manufacturer’s servicing instructions list for that boiler. In one manufacturer’s manual, that is an operation and fault history check, visual inspection inside and out, a gas leakage check, a fan pressure test, the condensate siphon, inlet pressure and gas rate, flue gas analysis at maximum and minimum output, flue integrity, a flame failure check and the inhibitor level.

Does the engineer have to take the boiler apart?

Not always. One manufacturer’s manual says the extent of the work is set by the operating condition of the appliance when tested. Another manufacturer’s manual sends the engineer to the full cleaning procedure when the combustion ratio is above 0.004, and to a shorter check procedure when it is below.

Is a boiler service the same as a gas safety certificate?

No. A landlord gas safety check is required by regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, at intervals of not more than 12 months, and covers each appliance and flue the landlord provides. A service is maintenance to the manufacturer’s instructions. HSE says not to assume one covers the other.

How often should a boiler be serviced?

HSE says in line with the manufacturer’s instructions, and annually where those are not available unless a Gas Safe registered engineer advises otherwise. The guarantee terms of three boiler manufacturers all require an annual service.

What paperwork should be left after a boiler service?

The two manuals summarised on this page tell the engineer to complete the Benchmark service record in the boiler manual after each service. It has space for the combustion readings at maximum and minimum rate, the gas rate, the flue integrity check, the inhibitor check, any parts fitted and the engineer’s Gas Safe registration number. Many engineers also send their own gas service record.

What does ClearWorks cost for service records?

The gas plan is £15 per engineer a month + VAT. Pay as you go is £2.50 a certificate + VAT. Your first 3 certificates are free.