A guide for householders, tenants and landlords.

Carbon monoxide alarm beeping: what the sounds mean

A loud carbon monoxide alarm that does not stop, with a red light flashing, means it has detected carbon monoxide: get everyone out and call 0800 111 999. One, two or three short beeps about once a minute, with a yellow or amber light, mean the alarm needs attention: low battery, fault or end of life. Sounds differ by model.

Last updated

First: is it the full alarm or a chirp?

A carbon monoxide alarm makes two main kinds of sound. In two manufacturers’ manuals they are easy to tell apart.

  • The full alarm is loud and does not stop. It repeats in groups of three or four pulses, with a red light flashing. It means the alarm has detected carbon monoxide.
  • A warning chirp is one, two or three short beeps, then quiet for most of a minute, with a yellow or amber light. It means the alarm itself needs attention.
  • Some chirps are about carbon monoxide. On some alarms a short chirp followed by a long one, or a regular beep with a red light, means a low level of carbon monoxide or an alarm that sounded earlier. The table below shows both.

If you cannot tell which one you are hearing, treat it as the full alarm. One manual says that if the alarm sounds, even when you are unsure of the cause, you should always evacuate.

This page is a summary, not emergency advice for your home and not your alarm’s instructions. Sounds and lights differ between makes and models, so follow the manual for your own alarm. ClearWorks is not affiliated with HSE, the NHS, UKHSA, Gas Safe Register, any gas network or any alarm manufacturer.

If it is the full alarm

The government’s public health guidance on carbon monoxide says that if your carbon monoxide alarm sounds:

  1. Stop using all appliances and evacuate the property immediately. Try to stay calm and avoid raising your heart rate.
  2. Call the National Gas Emergency Service on 0800 111 999 to report it.
  3. Do not go back into the property. Wait for advice from the emergency services.
  4. Get immediate medical help.

One gas network gives its steps in this order: open all doors and windows, move everyone into the fresh air, then call 0800 111 999. Both alarm manuals also say to open doors and windows, turn off fuel-burning appliances if possible and leave, and never to ignore this alarm. If the appliance burns oil or solid fuel, one manufacturer says to call your fuel supplier’s emergency number.

If you think a gas appliance is spilling carbon monoxide, HSE says to switch it off and shut off the gas at the meter control valve if you know where it is. Do not go back in to do it. Our gas emergency control valve guide shows where the valve is. Another gas network says not to try this in a block of flats or a multi-storey building.

Medical help

The NHS says to call 999 or go to A&E if someone who may have been exposed is finding it hard to breathe, has suddenly become confused, has lost consciousness, feels weak or has chest or muscle pain. It says not to drive yourself there. If you think you might have symptoms, such as a headache, dizziness or feeling sick, call NHS 111.

Afterwards

Both manuals say not to use the appliances again until an expert has checked them. One adds that the sensor can take up to 10 minutes to clear. HSE says it is illegal to use a gas appliance you suspect is unsafe, and not to touch it until a Gas Safe registered engineer has checked it.

What each sound means

These are the patterns in two manufacturers’ current manuals. They are not the same, so do not read one maker’s chart against another maker’s alarm.

Carbon monoxide alarm sounds in two manufacturers’ manuals
What it meansManufacturer AManufacturer B
Carbon monoxide detected (full alarm)Loud, repeating cycle of 3 pulses then a pause. Red light.Loud, 4 chirps repeated. Red flash every second.
Low battery1 beep and 1 yellow flash about every 48 seconds1 beep and 1 amber flash a minute
Fault2 short beeps and 2 yellow flashes about every 48 seconds2 rapid beeps and 2 amber flashes a minute
End of life3 short beeps and 3 yellow flashes about every 48 seconds3 rapid beeps and 3 amber flashes a minute
Low level of carbon monoxide, before the full alarmNo sound. The red light flashes above 43 ppm.On some models, 1 short then 1 long chirp every 25 seconds, with an amber flash

Manufacturer B’s help page gives its chirp interval as every 40 to 60 seconds, depending on the model.

Both manuals say an alarm with a fault, or at the end of its life, must be replaced. Manufacturer B says such an alarm may not detect a leak. For its low-level warning it says not to ignore it: open doors and windows and have a qualified engineer check the fuel-burning appliances. If anyone feels unwell, or the sound changes to the full alarm, follow the emergency steps above.

Still chirping after new batteries

New batteries only cure a low battery chirp. The manuals point to these other causes.

  • It is not a battery chirp. Count the beeps. Two or three in a group mean a fault or the end of the alarm’s life in both manuals. One manufacturer says an end-of-life alarm cannot be reset.
  • The alarm is past its date. One manual says to read the “Replace by” label before fitting batteries. If the date has passed, replace the whole alarm.
  • The batteries are flat or in the wrong way. That manual says to wait 15 seconds, then press the test button to check they are installed correctly and not depleted.
  • The alarm went off earlier. One manufacturer’s alarms give one regular beep every 40 to 60 seconds, with a red light, after carbon monoxide has been detected, possibly while you were out. Its manual says to ventilate and call a technician. Do not use the fuel-burning appliances until they have been checked.
  • It is a mains alarm running on its backup. One mains model chirps every 48 seconds when its backup battery has run down because the mains supply is off. Its manual says to check fuses and circuit breakers, or contact a qualified electrician, and that the chirps should stop within 2 hours of power returning.

Sealed alarms and how long alarms last

A sealed-for-life alarm has a battery you cannot change. When it gives the low battery chirp, the whole alarm is replaced. One manufacturer says to do that within 30 days.

Battery life differs. One manufacturer says its replaceable batteries usually last over 5 years in standby. The other says the batteries in its replaceable model last more than 1 year, and gives its sealed models a 10-year battery.

Both manufacturers give their alarms a life of 10 years and print a replace-by date on the alarm. HSE says alarms should comply with BS EN 50291 and be installed and maintained in line with the manufacturer’s instructions. For where one should go, see where to put a carbon monoxide alarm.

Testing, and who replaces a faulty alarm

Both manuals say to test the alarm every month with the test button. One says to hold the button for at least 5 seconds. The other says some of its models sound quietly on a single press and at full volume on a double press. One manual advises against testing with carbon monoxide gas.

Rented homes in England. HSE says that since 1 October 2022 relevant landlords must provide a carbon monoxide alarm in any room used as living accommodation that contains a fixed combustion appliance, other than a gas cooker. The government’s guidance says landlords are responsible for repairing or replacing a faulty alarm once they are told about it. Tenants are advised to replace the batteries first. If that does not work, or they cannot do it, they should report it to the landlord. Where a battery alarm is chosen, the same guidance calls sealed-for-life batteries the better option.

The same guidance covers smoke alarms. See our smoke alarm regulations guide.

For gas engineers

ClearWorks is a gas certificate app for Gas Safe registered engineers. When a call-out follows a carbon monoxide alarm, the visit goes on the breakdown record, which sets out the faults found and the work done. Mark an appliance unsafe and the warning notice opens for you. It works with no signal and sends when you are back online. You remain responsible for the inspection and the record.

See the gas certificate app. For a boiler that will not light, see boiler ignition lockout.

Sources: UK Health Security Agency, Carbon monoxide: general information (GOV.UK). HSE, Carbon monoxide awareness: frequently asked questions. HSE, Gas safety: frequently asked questions. NHS, Carbon monoxide poisoning. SGN, Carbon monoxide. Northern Gas Networks, Carbon monoxide. GOV.UK, Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022: guidance for landlords and tenants. Aico, Ei207/Ei208 series carbon monoxide alarm instructions (Rev 10). Aico, Ei3018/Ei3028 series instructions (B20225-R6). FireAngel, FA3313, FA3322, FA3328 and FA3820 user manual (GN5672R4). FireAngel, CO alarm beeping? What it means and what to do. FireAngel, What to do if your carbon monoxide alarm goes off. Last checked 18 November 2026.

Carbon monoxide alarm beeping questions

Why is my carbon monoxide alarm beeping?

A loud alarm that keeps repeating means carbon monoxide has been detected. A short chirp about once a minute is a warning about the alarm itself. In two manufacturers’ manuals, one beep means low battery, two mean a fault and three mean the alarm has reached the end of its life.

What should I do if my carbon monoxide alarm goes off?

Government public health guidance says to stop using all appliances and evacuate the property immediately, call the National Gas Emergency Service on 0800 111 999, not go back in, and get immediate medical help.

Why is my carbon monoxide alarm chirping after I changed the batteries?

New batteries only cure a low battery chirp. Two or three beeps in a group mean a fault or the end of the alarm’s life in two manufacturers’ manuals, and the alarm must then be replaced. Also check the replace-by date and that the batteries are the right type and fitted correctly.

How long does a carbon monoxide alarm last?

Two manufacturers’ manuals both give their alarms a life of 10 years, with a replace-by date printed on the alarm. Check the date on your own alarm.

Can I change the battery in a sealed carbon monoxide alarm?

No. A sealed-for-life alarm has a built-in battery. When it gives the low battery chirp, the whole alarm is replaced. One manufacturer says to do that within 30 days.

How often should I test a carbon monoxide alarm?

Two manufacturers’ manuals both say every month, using the test button. Follow the instructions for your own alarm.