A guide for landlords, tenants and gas engineers.
Gas safety check: what is checked
A gas safety check is the yearly inspection of the gas appliances and flues a landlord provides, done by a Gas Safe registered engineer. By law it must examine at least four things on each appliance: the flue’s effectiveness, the combustion air supply, the operating pressure or heat input, and safe functioning. HSE’s L56 guidance adds further checks.
Last updated
The four things the law says must be examined
A landlord gas safety check is the yearly inspection of the gas appliances and flues a landlord provides in a rented home. It must be done by a Gas Safe registered engineer.
Regulation 36(9) of the Gas Safety (Installation and Use) Regulations 1998 sets the minimum. Every safety check must examine the four matters in regulation 26(9):
- The flue. Whether it is effective at taking the products of combustion away.
- Combustion air. Whether the appliance has the air supply it needs.
- Operating pressure or heat input. One or, where necessary, both. Where it is not reasonably practicable to examine them, the engineer examines combustion performance instead.
- Safe functioning. How the appliance operates, so that it works safely.
The wording is “shall include, but shall not be limited to”, so the check can go further than those four.
This page is a summary, not a procedure. Follow the Regulations, HSE’s Approved Code of Practice (L56), current standards and the appliance manufacturer’s instructions. The engineer remains responsible for the inspection and the record. ClearWorks is not affiliated with HSE, IGEM or Gas Safe Register.
What is checked, step by step
L56, HSE’s Approved Code of Practice and guidance, has an appendix on what safety check work on appliances and flues should cover. The table summarises it.
| Step | What the engineer confirms |
|---|---|
| 1. The appliance and where it is | It suits the gas being supplied and the room it is in. It is stable, securely fitted and properly connected. |
| 2. Ventilation | The room has a permanent air supply that is enough for safe combustion. Air vents are the right type and size. Changes such as new windows or draught proofing are taken into account. |
| 3. The flue or chimney | It is complete, continuous, undamaged and supported along its length, including through any roof space or void. The terminal is correctly sited. |
| 4. Flue performance | For open or closed flues (not room-sealed), a flue flow test. Once that is satisfactory, a spillage test with the appliance connected and running. Both follow the manufacturer’s instructions. |
| 5. Gas tightness | The appliance is gas-tight. |
| 6. Pressure or heat input | Where it can be measured, the operating pressure or heat input matches the manufacturer’s instructions or the data badge. |
| 7. Combustion | Combustion performance is measured where the manufacturer specifies it. The flame picture is checked by eye where it can be seen. |
| 8. Safety devices and seals | Flame protection, fan proving and other safety devices work. Case seals make an effective seal. |
For steps 6 and 7, see the gas rate calculator and the flue gas analyser guide.
What is in the check and what is not
- In: every appliance the landlord provides. Permanent and portable. HSE says a mobile LPG space heater needs a check too.
- In: flues serving those appliances, and communal appliances, such as a shared boiler, that tenants use.
- Not the landlord’s duty: an appliance the tenant owns, or a flue that serves only that appliance. HSE still recommends including every flue connected to a gas appliance in the check.
- Not in the yearly check: installation pipework. The landlord must still keep it safe. HSE recommends asking the engineer to test the whole gas system for soundness and to look over the pipework as far as is reasonably practicable.
That soundness test is the gas tightness test.
A safety check is not a service. HSE tells landlords not to assume a service covers the points a safety check needs, or that a safety check is enough to maintain an appliance. A service follows the manufacturer’s instructions. See what a boiler service includes.
How the check ends
- No defects found. The engineer issues the record. L56 says it should not be issued until every required test has been done on every relevant appliance and flue.
- A safety defect is found. It goes on the record, with any remedial action taken. HSE says the record is issued when the checks are complete and is not held back until repairs are done. L56 says the landlord should then act promptly to put the defect right.
- An appliance is unsafe. The engineer classifies it under the Gas Industry Unsafe Situations Procedure (IGEM/G/11) as Immediately Dangerous or At Risk. It must not be used until it is put right.
What the two classifications mean, and what the engineer does next, are on the gas warning notice page. For the items the paperwork must carry, see what has to be on the record. For prices, see gas safety certificate cost.
For engineers: the record, done at the property
ClearWorks is a certificate app for Gas Safe registered engineers. You fill in the record on your phone as you work through the check.
- Readings outside limits are flagged as you type
- Combustion ratio and purge worked out for you
- Mark an appliance unsafe and the warning notice opens itself
- Sent to the landlord, agent and tenant before you leave
- Reminders go out before the next check is due
- Works with no signal, and sends when you’re back online
The Gas plan is £15 per engineer a month plus VAT. Pay as you go is £2.50 a certificate plus VAT. Your first 3 certificates are free. See the gas certificate app or pricing.
Sources: Gas Safety (Installation and Use) Regulations 1998, regulation 36. Regulation 26(9). HSE, L56 Approved Code of Practice and guidance, fifth edition (Appendix 3; paragraph 302). HSE, Gas safety checks: what needs them?. HSE, Maintenance: gas appliances and flues. HSE, Gas safety: landlords and letting agents. IGEM, IGEM/G/11 Edition 2. Last checked 18 November 2026.
Gas safety check questions
What is checked in a gas safety check?
By law, at least four things on each appliance: the effectiveness of the flue, the supply of combustion air, the operating pressure or heat input, and that the appliance works safely. HSE’s code of practice and guidance (L56) adds checks such as ventilation, gas tightness, safety devices and case seals.
What does a gas safety check involve for a tenant?
The engineer needs to reach every gas appliance and flue the landlord provides, run each appliance and test it. HSE says the tenancy agreement should allow access for safety checks, and that a landlord must not use force to enter.
How long does a gas safety check take?
The Regulations do not set a time. It depends on how many appliances and flues there are and how easy they are to reach. HSE’s code of practice says the record should not be issued until every required test has been completed.
Is a gas safety check the same as a boiler service?
No. HSE tells landlords not to assume a service includes the points a safety check requires, or that a safety check is enough to maintain an appliance. A service follows the manufacturer’s instructions.
Does the gas safety check cover the tenant’s own cooker?
Not as part of the landlord’s duty. HSE says tenants are responsible for their own appliances, and for a flue that serves only their appliance. The landlord is still responsible for parts of the installation and pipework that supply it.
Related pages
Record your next gas safety check in ClearWorks
Your first 3 certificates are free. No card needed.