Guide for gas engineers and householders.
Gas emergency control valve (ECV)
The gas emergency control valve (ECV) shuts off the gas supply to a property in an emergency and in most homes is next to the gas meter. It is on when the handle is in line with the pipe and off when turned a quarter turn to sit across it. Smell gas? Call 0800 111 999.
Last updated
What the emergency control valve is
The emergency control valve (ECV) is the valve that shuts off the gas to a property in an emergency. The Gas Safety (Installation and Use) Regulations 1998 call it an “emergency control” and define it by who it is for: it is a valve for shutting off the gas supply in an emergency that is meant to be used by the gas consumer. Where a meter is fitted, HSE’s Approved Code of Practice and guidance (L56) says the meter control valve can serve as the emergency control, provided it meets the siting conditions below.
It also marks a boundary. The service pipe runs from the main to the outlet of the first emergency control. Installation pipework starts after it.
This page is a summary, not the regulations or the standards. Engineers must follow the current regulations, standards and manufacturer’s instructions, and remain responsible for their work. ClearWorks is not affiliated with HSE, Gas Safe Register, IGEM or any gas network. In an emergency call 0800 111 999.
Where to find it
In most homes the ECV is next to the gas meter. Gas networks list the usual meter positions as outside at the front or side of the house, under the stairs, in the kitchen or in a garage. An outside meter box opens with a meter box key.
HSE’s guidance in L56 on siting says:
- Each individual premises, such as each house or flat, should have its own emergency control, whether or not it has a meter.
- It should be as near as reasonably practicable to where the gas supply enters the premises.
- It should be readily accessible to everyone who uses gas there. L56 gives a basement or cellar as an example of somewhere that is not.
- A valve in a locked meter room that only a landlord, supplier, transporter or the emergency service can reach does not count as an emergency control.
Flats and extra valves. A building can have more than one emergency control. In multi-occupancy premises, L56 says each consumer should know which control serves them, and landlords or managing agents should tell tenants where it is. A second valve inside the premises is usually called an additional emergency control valve (AECV). Registered Gas Engineer magazine says an AECV should be readily accessible and labelled as an additional gas emergency control, with the emergency number.
On or off: reading the handle
- On: the handle is in line with the pipe.
- Off: the handle is a quarter turn (90 degrees) round, at right angles to the pipe.
This is a legal requirement on whoever installs the valve. Regulation 9(2) says a key or lever must be parallel to the pipe when the control is open. Where the lever does not move only horizontally, the gas must be off when the lever is as far down as it will go. Cadent, SGN and Northern Gas Networks give householders the same instruction: turn the handle 90 degrees so it sits across the pipe.
The handle or a permanent notice next to it must also show when the control is open and when it is shut. A hand-wheel must show the direction to open or close.
If you smell gas
Call the National Gas Emergency Service on 0800 111 999. It is free and answered 24 hours a day.
- Turn the gas off at the ECV if you know where it is and it is safe to reach. Do not go into a cellar or basement to do it. Leave the building instead.
- Open doors and windows to let the gas out.
- Do not turn any switch on or off, including lights, and do not use anything that could make a spark.
- No flames. Put out naked flames. Do not smoke, vape or strike a match.
- Keep people away and move outside if you can.
- Leave the gas off. Do not turn it back on until you are told it is safe.
These steps are taken from HSE, Cadent and Northern Gas Networks advice. Follow the emergency call handler’s instructions if they differ.
Who owns it and who can work on it
The split follows the boundary at the ECV outlet:
| Part | Who looks after it |
|---|---|
| Pipes in the street and the service pipe up to the meter, ending at the ECV outlet | The gas network (the gas transporter). L56 says service pipes are normally the transporter’s property. |
| The meter | The gas supplier, according to Cadent. |
| Pipework from the meter to the appliances, and the appliances | The householder or the landlord. |
For engineers this means the ECV is not yours to strip, swap or adjust on a customer’s job. L56 says the transporter must be told before any work on a service pipe. Wales & West Utilities describes exchanging a customer’s ECV as network work, usually done after a gas leak or when the valve itself is leaking.
Stiff, seized or out of reach. Do not force it. SGN’s advice is that if you cannot turn the valve off, or need help doing so, you should call the National Gas Emergency Service on 0800 111 999. Cadent fits a push-button ECV free for eligible Priority Services Register customers on its network who struggle with a standard handle.
What the regulations ask of engineers
- No first supply without one. Nobody may enable gas to be supplied to premises for the first time unless there is an appropriately sited emergency control with adequate access (regulation 9(1)).
- Fit the handle properly. Anyone installing an emergency control must make sure the key, lever or hand-wheel is securely attached to the spindle (regulation 9(2)).
- Notice at the control. If the control is not next to a primary meter, the installer must straight away display a permanent notice on or near it giving the procedure for a gas escape (regulation 9(3)).
- Notice at the meter. Whoever supplies gas through a primary meter must make sure a permanent emergency notice is displayed on or near it. If the meter is more than 2 metres from the nearest upstream emergency control, or out of sight of it, a notice at the meter must say where the control is (regulation 15).
- Closing the ECV is not capping off. L56 says closing an emergency control does not meet the duty to seal an open gasway with an appropriate fitting before leaving work unattended (regulation 6).
- Do not turn back on too soon. Where an escape was stopped by shutting off the supply, it must not be re-opened, other than in the course of repair, until the steps needed to stop it happening again have been taken (regulation 7(9) of the Gas Safety (Management) Regulations 1996 for network gas; regulation 37(4) of the 1998 Regulations otherwise).
L56 says the notice should bear the words “Gas emergency control”. It should tell the consumer to shut off the supply if gas escapes, to call the emergency number if it keeps escaping, and not to restore the supply until a competent person has dealt with the cause. It should also show the date it was first displayed.
Proving it shuts. The let-by stage of a tightness test is what shows the ECV closes fully. The method and timings are in our gas tightness test guide.
How fast the network must act. For gas from a network, the Gas Safety (Management) Regulations 1996 require the company conveying gas immediately upstream of the emergency control to attend as soon as reasonably practicable after being told of an escape from a gas fitting, and to stop the escape within 12 hours. Regulation 37 of the 1998 Regulations puts a 12-hour duty on suppliers of gas that is not from a network.
Recording what you find
ClearWorks is a certificate app for gas engineers. It covers the landlord gas safety record, the warning notice, and service and breakdown records. Mark an appliance unsafe and the warning notice opens itself.
Sources: Gas Safety (Installation and Use) Regulations 1998, regulation 2 (definitions of emergency control and service pipe), regulation 9 (emergency controls), regulation 15 (meter notices) and regulation 37 (escape of gas). Gas Safety (Management) Regulations 1996, regulation 7 (network gas escapes, 12 hours). HSE, L56 Safety in the installation and use of gas systems and appliances, fifth edition (paragraphs 25–26, 46, 115, 150–157, 183–186). HSE, domestic gas FAQs and HSE, landlords: gas pipework. Cadent: finding your meter and turning off the gas, smell gas, emergency engineer visit, EasyAssist. Northern Gas Networks, smell gas. SGN: flooding advice and self-isolation label. GTC, gas meters. Wales & West Utilities, safer gas supply isolation. Registered Gas Engineer, “Commercial valves: identification and use”, 3 May 2024 (AECV). Last checked 18 November 2026.
Questions about the gas ECV
What does ECV stand for in gas?
Emergency control valve. It is the valve, usually next to the gas meter, that shuts off the gas supply to the property in an emergency. The regulations call it an emergency control.
Is the gas on or off when the handle is in line with the pipe?
On. The handle is in line with the pipe when the gas is on. A quarter turn, so the handle sits at right angles to the pipe, turns it off. Follow the on/off label where there is one.
How do I turn off the gas at the meter?
Find the handle on the pipe next to the meter and turn it a quarter turn so it sits across the pipe. If you smell gas, call the National Gas Emergency Service on 0800 111 999. Do not go into a cellar or basement where there is a smell of gas.
Who is responsible for the emergency control valve?
On a mains gas supply the service pipe, which ends at the outlet of the first emergency control, is normally the property of the gas transporter, meaning the local gas network. The householder or landlord is responsible for the pipework from the meter to the appliances.
What if the gas valve at the meter is stiff or will not turn?
Do not force it. If you cannot turn the valve off, call the National Gas Emergency Service on 0800 111 999. If you would always struggle with the handle, ask your gas network what help it offers.